Tuesday, September 9, 2014

Bonding of plastic pipes do not worry, it is simply useless, but given the notoriously desperate co


News: PLEASE ALL USERS, PLEASE READ BEFORE USING LOCAL DISCUSSION RULES! HERE! ... Discussion Elektrika.cz public, consumers, non-professionals, handymen, laity Verify wiring, appliances, tools No risk of danger to my family if I changed Fittings for plastic tubes? 0 Members and 1 Guest are viewing this topic. Previous next Pages: [1] Note! The answers to the themes are not legally binding! The electrical equipment may only be operated by authorized personnel in accordance with Decree 50/78 Sb. The decree here ...
Recently we changed the pipes in a block of flats ... There is already everything in plastic water pipes and water pipes ... K resulted in a lot of "Wire" ... and from Formica core, bathtubs, water heaters, etc.. Probably were some additional grounding wires are attached ... while ago, but already pipes are made of plastic, so it's probably a connection would not be at all. Those "rednecks" what we did barely tapped the tubes, let alone to understand and even electrics. No risk my family in any danger, it is clear to me that electricity is not to be trifled with? There is a network of TN-C! Terms debates Report to moderator Complain to moderator Logged Milan Illek Offline
According to the description done by the company in exchange piping in your house partial sabotage the electrical system. I recommend to leave immediately perform electrical inspections and detected according to the defects repaired the damaged section of wiring. The cost to recover from the company that caused the damage. Next, consider the reconstruction of the whole wiring. Not to solve yourself !! Asked whether there is a risk odpovídánám positively. Terms debates Report to moderator Complain to moderator Logged Lubomir Jindra Inspection technician E2 / A Offline electrician. The head and hands.
Bonding of plastic pipes do not worry, it is simply useless, but given the notoriously desperate condition fox river resort of such older wiring (I will not elaborate), I would recommend you contact the building manager and have at least revise the riser, which does not want to question the skill guys paťatých boating rules debates Report to moderator Complain to moderator Logged
Bonding of plastic pipes do not worry, it is simply useless, but given the notoriously desperate condition of such older wiring (I will not elaborate), I would recommend you contact the building manager and have at least revise the riser, which does not want to question fox river resort the skill guys boating paťatých not perhaps the bonding of plastic fox river resort pipes, but that was discontinued existing fox river resort bonding and grounding conductors PEN removing metal pipe. Terms debates Report to moderator Complain to moderator Logged Lubomir Jindra Inspection technician E2 / A Offline electrician. The head and hands.
It is not perhaps the bonding of plastic pipes, but that was discontinued existing bonding and grounding conductors PEN removing metal pipe. Exactly rules debates Report to moderator Complain to moderator Logged
It is not perhaps the bonding of plastic pipes, but that was discontinued existing bonding and grounding conductors PEN removing metal pipe. I did not want to describe them, but overcome laziness in these older installations TN-C wherein the metal bonding riser on each floor of the residential distribution boards, may increase the resistance at the terminals in metering cabinet (old wires AL) happen, the PEN feeds rather than from its own supply pipes and the defect is not observed! Such interruptions metal pipes can then be unpleasant and dangerous consequences, either immediately or in the short term discussions Rules Report to moderator Complain to moderator Logged
notify the Police danger electric shock will not get anything else! (One solution would be that during the exchange of metallic water pipes for plastic should fox river resort stretched wire or tape 10 FeZn 04.30 and it has been disconnected from the pipe must be connected to another conductor within the meaning of formerly valid standard ČSN 34 10 10!) Is clear that it would be best to reconstruct all the electrics in connection with new standards and regulations (TN-S system, chánič ....) Rules debates Report to moderator Complain to moderator Logged Pages: [1] previous next WATCH HERE similar topics fox river resort ! Related discussions and articles Kutil.elektrika.cz
How to determine the buffer zone of the MV line from my property? It's not a luxury, a separate RCD for gas. boiler? I really connected with such appliances burn out? There RCD without mounting the rack? Are safe 4-wire cables (380V) fox river resort for engagement techniques

No comments:

Post a Comment